PWR-C1-1100WAC
|
PWR-C1-715WAC
|
PWR-C1-350WAC
|
PWR-C1-440WDC
|
Power supply rated maximum
|
1100W
|
715W
|
350W
|
440W
|
Total output BTU (Note: 1000 BTU/hr = 293W)
|
3793 BTU/hr, 1100W
|
2465 BTU/hr, 715W
|
1207BTU/hr, 350W
|
1517BTU/hr, 440W
|
Input-voltage range and frequency
|
115-240VAC,
50-60 Hz
|
100-240VAC,
50-60 Hz
|
100-240VAC,
50-60 Hz
|
-36VDC to -72VDC
|
Input current
|
12-6A
|
10-5A
|
4-2A
|
<8A at -72VDC
<16A at -36VDC
|
Output ratings
|
-56V at 19.64A
|
-56V at 12.8A
|
-56V at 6.25A
|
-56V at 7.86A
|
Output holdup time
|
10 ms minimum at 102.5VAC
|
16.7 ms minimum at 100VAC
|
16.7 ms minimum at 100VAC
|
> 2ms at -48VDC
|
Power-supply input receptacles
|
IEC 320-C16
(IEC60320-C16)
|
IEC 320-C16
(IEC60320-C16)
|
IEC 320-C16 (IEC60320-C16)
|
Terminal strip
|
Power cord rating
|
13A
|
13A
|
10A
|
20A at 100VDC
|
Physical specifications
|
(H x W x D): 1.58 X 3.25 X 13.7 in
Weight: 3 lb (1.4 kg)
|
(H x W x D): 1.58 X 3.25 X 12.20 in
Weight: 2.8 lb (1.3 kg)
|
(H x W x D): 1.58 X 3.25 X 12.20 in
Weight: 2.6 lb (1.2 kg)
|
(H x W x D): 1.58 X 3.25 X 12.20 in
Weight: 2.6 lb (1.2 kg)
|
Operating temperature
|
23 to 113°F (-5 to 45°C)
|
Storage temperature
|
-40 to 158°F (-40 to 70°C)
|
Relative humidity operating and nonoperating noncondensing
|
5 to 90% noncondensing
|
Altitude
|
10,000 ft. (3000 meters), up to 45°C
|
MTBF
|
Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hr (with 90% confidence level).
|
EMI and EMC compliance
|
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
BSMI Class A (AC input models only)
VCCI Class A
EN 55024, EN300386, EN 50082-1, EN 61000-3-2, EN 61000-3-3
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1
|
Safety compliance
|
UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking
|
LED indicators
|
“AC OK”: Input power to the power supply is OK
“PS OK”: Output power from the power supply is OK
|