The Cisco industrial din-rail power supplies offer a variety of rugged, reliable, and compact AC and DC power supply options to power Cisco’s industrial Ethernet switches, industrial routers (including industrial gateways), and industrial computing products. Some key features include:

      Power supply options from 50W to 480W

      Operating temperatures ranging between -40°C and +85°C

      Din-rail mountable options

      Enablement of high capacity Power over Ethernet (PoE)

      Conformal coating options

Din-rail power supplies part numbers and descriptions

Part number

Product description

PoE / PoE+ support

PWR-IE50W-AC-L=

50W AC to DC power supply

No

PWR-IE50W-AC=

50W AC to DC or High DC to DC power supply

No

PWR-IE50W-AC-IEC=

50W AC to DC power supply with an IEC connector

No

PWR-IE65W-PC-AC=

65W AC to DC or High DC to DC power supply

Yes

PWR-IE65W-PC-DC=

65W Low DC to DC power supply

Yes

PWR-IE170W-PC-AC=

170W AC to DC or High DC to DC power supply

Yes

PWR-IE170W-PC-DC=

170W Low DC to DC power supply

Yes

PWR-IE240W-PCAC-L=

240W AC to DC power supply

Yes

PWR-IE480W-PCAC-L=

480W AC to DC power supply

Yes

Product specifications

lists the input specification for Cisco industrial power supplies. Table 3 lists the output specifications.

Product ID

Rated nominal input operating range

Supported input voltage operating range

Typical efficiency

Inrush current at 25C ambient

Remarks

PWR-IE50W-AC-L=

AC 100-240V/1.2A, 50-60Hz

AC 90-264V

88%

< 35A @ 115VAC and 70A @ 230VAC

Not approved for hazardous location installations

PWR-IE50W-AC=

AC 100-240V/1.25A, 50-60Hz

or

DC 125-250V/1.25A

AC 90-264V

or

DC 106-300V

80%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1,

Div 2/Zone 2 installations

PWR-IE50W-AC-IEC=

AC 100-240V/1.25A, 50-60Hz

AC 90-264V

80%

< 35A @ 115VAC and 70A @ 230VAC

Not approved for hazardous location installations

PWR-IE65W-PC-AC=

AC 100-240V/1.4A, 50-60Hz

or

DC 125-250V/1.0A

AC 90-264V

or

DC 106-300V

85%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1,

Div 2/Zone 2 installations

PWR-IE65W-PC-DC=

DC 24-48VDC/4.5A

DC 18-60V

92%

4A@24VDC

Approved for Class 1,

Div 2/Zone 2 installations

PWR-IE170W-PC-AC=

AC 100-240V/2.3A, 50-60Hz

or

DC 125-250V/2.1A

AC 90-264V

or

DC 106-300V

88%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1,

Div 2/Zone 2 installations

PWR-IE170W-PC-DC=

DC 12-54V/2.3A

DC 10.8-60V

88%

17.3A @ 12VDC

Approved for Class 1,

Div 2/Zone 2 installations

PWR-IE240W-PCAC-L=

AC 100-240V/3.5A, 50-60Hz

AC 90-264V

91%

< 35A @ 115VAC

and 230VAC

Not approved for hazardous location installations

PWR-IE480W-PCAC-L=

AC 100-240V/6A, 50-60Hz

AC 90-264V

92%

< 35A @ 115VAC

and 230VAC

Not approved for hazardous location installations

Output specifications

Product ID

Nominal output voltage / adjustment range

Max output power

Holdup time at 100% load

Protections

PWR-IE50W-AC-L=

24VDC / 24-28VDC, 2.1A

50W

20ms

Over voltage protection

Over current protection

Over temperature protection

Short circuit protection

PWR-IE50W-AC=

24VDC, 2.1A

50W

20ms

PWR-IE50W-AC-IEC=

24VDC, 2.1A

50W

20ms

PWR-IE65W-PC-AC=

54VDC, 1.2A

65W

10ms

PWR-IE65W-PC-DC=

54VDC, 1.2A

65W

 

PWR-IE170W-PC-AC=

54VDC, 1.3A

170W

20ms

PWR-IE170W-PC-DC=

54VDC, 3.2A

170W

9ms (@10.8VDC) to 25.9ms (@ 60VDC)

PWR-IE240W-PCAC-L=

54VDC / 48-56VDC, 4.5A

240W

20ms

PWR-IE480W-PCAC-L=

54VDC / 48-56VDC, 8.9A

480W

20ms

Environmental specifications

Product ID

IP rating

Operating temperature

Storage temperature

Power de-rating

Operating humidity

PWR-IE50W-AC-L=

IP20

-20°C to +70°C

-40°C to +85°C

> 55°C de-rate power by 3.33%/°C

< -10°C de-rate power by 2%/°C

5 to 95% RH

(non-condensing)

PWR-IE50W-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE50W-AC-IEC=

IP20

-20°C to +70°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE65W-PC-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE65W-PC-DC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE170W-PC-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE170W-PC-DC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE240W-PCAC-L=

IP20

-40°C to +80°C

-40°C to +85°C

Vertical mounting:

> 50°C de-rate power by 2.5%/°C

Horizontal mounting:

> 40°C de-rate power by 2.5%/°C

5 to 95% RH

(non-condensing)

PWR-IE480W-PCAC-L=

IP20

-40°C to +75°C

-40°C to +85°C

Vertical mounting:

> 50°C de-rate power by 2.5%/°C

> 70°C de-rate power by 5%/°C

5 to 95% RH

(non-condensing)

Safety standards / EMC

Product ID

Electric safety

EMC/ Industry standards

PWR-IE50W-AC-L=

CE (EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC)

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1

UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1

UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01

CB scheme to IEC 60950-1, LPS

NEC Class 2

EN 61000-3-2 Class A, EN 61000-3-3

EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4,

EN 61204-3, EN 55024 (EN 61000-4-2,3,4,5,6,8,11 LEVEL 3, Performance Criteria A)

CISPR 22, EN 55022, CISPR 11, EN 55011,

FCC part 15B

PWR-IE50W-AC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12:

2011+A2: 2013, EN61131-2: 2007

EN62368-1: 2014 + A11: 2017

IEC60950-1: 2005+A1: 2009+A2: 2013

IEC62368-1: 2014

EN 60079-0:2012 + A11:2013, EN 60079-15:2010

CE

EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11

IEC61000-4-11, IEC61000-4-12, IEC61000-4-16

FCC part 15B

PWR-IE50W-AC-IEC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN62368-1: 2014 + A11: 2017

CE

EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11

IEC61000-4-11, IEC61000-4-12, IEC61000-4-16

FCC part 15B

PWR-IE65W-PC-AC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014

UL 508

Class 1, Div 2/ Zone 2 Hazardous location

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12, EN61131-2: 2007

EN 55032: 2012/AC: 2013, EN 55024: 2010

FCC part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE65W-PC-DC=

EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013

UL 508

Class 1, Div2/ Zone 2 Hazardous Location

CCC

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8,

EN 55032:2015, EN 55024: 2010+A1:2015

EN55032:2015, EN 55024: 2010

FCC part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE170W-PC-AC=

IEC60950-1: 2005+A1: 2009+A2: 2013 EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013,

KCC mark, BSMI mark, CCC, CB Scheme,

Class 1, Div2/ Zone 2 Hazardous Location

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12

EN 55032: 2012/AC: 2013, EN 55024: 2010

FCC part 15B

EN61131-2: 2007

IEC 61850-3, IEEE 1613

PWR-IE170W-PC-DC=

EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013

UL 508

Class 1, Div 2/Zone 2 Hazardous location

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8,

EN 55032:2015, EN 55024: 2010+A1:2015

EN55032:2015, EN 55024: 2010

FCC part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE240W-PCAC-L=

SIQ Bauart to EN 60950-1

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1

UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)

CSA C22.2 No. 107.1-01 (File No. 181564)

EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2,

EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12 LEVEL 3, Performance Criteria A)

CISPR 32, EN 55032, CISPR 11, EN 55011,

FCC Title 47: Class A

PWR-IE480W-PCAC-L=

SIQ Bauart to EN 60950-1

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1

UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)

CSA C22.2 No. 107.1-01 (File No. 181564)

EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2,

EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12 LEVEL 3, Performance Criteria A)

CISPR 32, EN 55032, CISPR 11, EN 55011,

FCC Title 47: Class A

Mechanical / Reliability data

Product ID

Dimensions (W x H x D)

Unit weight

MTBF (Telcordia SR-332)

PWR-IE50W-AC-L=

30 mm x 75 mm x 89.5 mm

1.18 in x 2.95 in x 3.52 in

0.39 lb (0.18 kg)

2,255,613 hours

PWR-IE50W-AC=

51 mm x 118 mm x 148 mm

2 in x 4.64 in x 5.82 in

1.41 lb (0.64 kg)

1,662,359 hours

PWR-IE50W-AC-IEC=

51 mm x 118 mm x 148 mm

2 in x 4.64 in x 5.82 in

1.43 lb (0.65 kg)

1,662,359 hours

PWR-IE65W-PC-AC=

63.5 mm x 148 mm x 118 mm

2.5 in x 5.82 in x 4.64 in

2.64 lb (1.2 kg)

2,488,401 hours

PWR-IE65W-PC-DC=

66 mm x 150 mm x 117 mm

2.59 in x 5.90 in x 4.60 in

2.60 lb (1.18 kg)

4,802,673 hours

PWR-IE170W-PC-AC=

96 mm x 150 mm x 146 mm

3.77 in x 5.90 in x 5.74 in

3.88 lb (1.76 kg)

2,384,975 hours

PWR-IE170W-PC-DC=

114 mm x 150 mm x 146 mm

4.48 in x 5.90 in x 5.74 in

3.68 lb (1.67 kg)

2,164,641 hours

PWR-IE240W-PCAC-L=

85 mm x 121 mm x 124.1 mm

3.34 in x 4.76 in x 4.88 in

2.11 lb (0.96 kg)

1,579,900 hours

PWR-IE480W-PCAC-L=

144 mm x 121 mm x 118.6 mm

5.66 in x 4.76 in x 4.66 in

3.02 lb (1.37 kg)

1,058,750 hours

Ordering information

provides ordering information for Cisco industrial power supplies.

Part #

Product description

PWR-IE50W-AC-L=

50W AC to DC power supply

PWR-IE50W-AC=

50W AC to DC power supply

PWR-IE50W-AC-IEC=

50W AC to DC power supply with IEC connector

PWR-IE65W-PC-AC=

65W AC to DC power supply

PWR-IE65W-PC-DC=

65W DC to DC power supply

PWR-IE170W-PC-AC=

170W AC to DC power supply

PWR-IE170W-PC-DC=

170W DC to DC power supply

PWR-IE240W-PCAC-L=

240W AC to DC power supply

PWR-IE480W-PCAC-L=

480W AC to DC power supply

Warranty information

Cisco offers a five-year limited warranty on all industrial Ethernet power supplies. Warranty information is available at https://www.cisco-servicefinder.com/warrantyfinder.aspx.

ข้อมูลเพิ่มเติม
ข้อมูลเพิ่มเติม
ประเภท Industrial Power Module
Model Industrial Power Supply
License / Features For Cisco Industrial Networks
รีวิวสินค้า
เขียนรีวิวสินค้าของคุณเอง
คุณกำลังรีวิว: Cisco Industrial Power Supply | PWR-IE50W-AC-L Industrial Din-Rail Power Supplies 50W AC to DC
คุณจะให้คะแนนสินค้านี้อย่างไร? *
  1 ดาว 2 ดาว 3 ดาว 4 ดาว 5 ดาว
บริการ
ราคา